PROFILE
The 40 TB is
a microprocessor based, 2-channel alarm unit, format
96x96 (1/4 DIN), manufactured with SMT. Its operator
interface is comprehensive and efficient, with two
4-digit displays for the two process variables and
engineering units indications. It is also equipped
with a red LED bar graph, which can be associated to
process variables and to peak values. Three
LEDs indicate the output status, while 3 more LEDs
can be configured to indicate different functional
conditions.
The instrument has a lexan membrane faceplate (guaranteed
to IP65) with 4 keys.
Channel 1 has strain gauge, pressure or force sensor
inputs, with positive or symmetrical polarisations,
calibration with sensitivity auto-calculation (from
1,5 up to 4 mV/V), indication of probe power supply
break. The first input channel can also receive signals
from potentiometers with 100 Ohm min. resistance.
The A/D converter
performance can be configured via keyboard, so that
different options of sampling time can be selected,
depending on the desired resolution. Sampling time
can be as low as15msec., while resolution can reach
a max. value of 16,000 divisions (by a 120msec. sampling
time).
The second input channel can be configured for inputs
from temperature sensors (TC, RTD, PTC, NTC) and for
mV, V, mA signals, with the ability to have of having
a customized input for each kind of sensor. The selection
of the different options is available from keyboard.
There is the possibility of having two digital
inputs from voltage-free contacts, configurable
for functions such as reset, hold, flash, peak or memory
reset control.
The instruments can be equipped with up to three relay
(5A/250V) or static (0-11Vdc) outputs. Two voltage
or current analogue outputs are available for the retransmission
of inputs, of alarm sets, of gross and tare values.
The serial communication option may have current
loop, RS422/ 485 and RS232 connections with baud
rate up to 19200. The option "transmitter
power supply" is
foreseen for each input channel. For channel 1 it could
be: 1V (potentiometer), 5 and 10V (strain-gauge), 15
and 24V; for channel 2: 15 and 24Vdc.
The programming of the instrument is made easy by grouping
the parameters in function blocks and by a simplified
data entry menu.
The configuration can be simplified
even further using the PC programming kit containing
connection cable and a menu guide program that
runs under Windows (see technical data code 80020).
A configurable personal software protection code
(password protection) can be used to restrict the
levels of editing and displaying the configuration
parameters.