1. Measuring Range (Maxi) : Refer to Table(1)
2. Dead Band . : Refer to Table(1)
3. Transducer Frequency : 50K HZ
4. Transducer Material : Glass Reinforced Epoxy
Housing with P.P. or PVDF
5. Beam Angle : 5 ° @ 3db point
6. Measurement Accuracy : 0.25% of measuring range
for Solid application, 0.2% of measuring range
for liquid/open chanel
7. Resolution Ambient : 1mm (0.04 inch )
8. Power Supply : 18~30 Vdc ( 0.25A Maxi.)
100~230 Vac,50/60 HZ, 70mA Maxi.)
9. Operation Temp (In Tank) : -40 ° C ~+ 100 ° C ( -40 ° F ~ 140 ° F )
10. Ambient Temperature Compensation : Intergral
11. Operation Pressure : Up to 5 bar (75 PSI)
12. Process Mounted : 1" NPT or 1" BSP
13. Housing type : Two Parts
14. Housing Material : ABS + UV
15. Enclosure Rating : IP67
16. Display : LCD (6digital)
17. Linear Output : 4~20mA, 4 wire 750Ohm @24Vdc
18. Relay Output : 5 x SPDT
19. Communication/PC Interface (Option order) :
Option:RS-485 Modbus Protocol, HART
20. Enclosure Dimesion : 246mm x 200mm x 84mm
21. Extension Cable Length : Up to 200 Meter
22. Weight : 1.6kg ( 3.3LB )
23. Certificates : CE,FCC, 3A ,CSA,FM |